Measurement Principle:
Enhanced Chemiluminescence

MicroWell Technology:
Excellent assay sensitivity and precision, small sample volumes and minimal waste

Reagents:
No preparation; no mixing and reconstitution required for Integrated Reagent Packs, Signal Reagent and Universal Wash Reagent

On-Board Test Capacity:

  Up to 2000 assays
  Up to 20 different Integrated

Reagent Packs

  100 assays each
 Resident on-board simultaneously
  Automatic, self-contained, temperature and humidity controlled Reagent Supply

Calibration:

Multiple lots may be pre-calibrated with automatic lot switching  

  Up to 28 days
  Process: Random Access Calibration with Automatic Result Protection; 25 calibrations across 16 lots per assay

System Startup:

Automatic Integrated Prime/Purge

  No primes, purges, washes or tubing maintenance
  No daily calibrations or calibration checks

Throughput:
Up to 90 reportable patient results per hour

Sample Types:
Serum, Plasma, Urine, Amniotic Fluid*, Whole Blood**

Sample Volume:
10-80µL

Sample Capacity:
60 samples in Universal Sample Trays

Sample Containers:
Universal Sample Trays accommodate: 

  10mL, 7mL, 5mL collection tubes
  1.5mL micro-collection containers
  VITROS®  Microsample cups and 0.5mL and 2.0mL cups

Sample and Reagent Management:
Intellicheck® Technology 
 

  Disposable Tip Metering verifies sample aspiration and dispense and addresses carryover and cross-contamination concerns
  Clot, bubble, low and high viscosity, thin layer fluid and short sample detection

  Save-the-Sample™ Clot/Bubble Management
  Liquid level sensing
  MicroWell Dispense Verification
  Reagent Aspiration and Dispense Verifications

Sample Bar Code Identification:
Autodiscriminates by simultaneously recognizing all standard symbologies: 
 

  Code 128
  ISBT 128
  Code 39
  Codabar
  Interleaved 2 of 5

Automatic Dilution:

  Reflex dilution
  Operator requested dilution
  Protocol and pre-treatment dilutions

Automatic Reflex Testing:

  Reflex to different assays
  Reflex to the same assay 

Automatic Repeat Testing:

Repeats samples automatically after a result is not initially reported for the sample

Operator Interface:
Color-coded graphical user interface 
 

  Ergonomic flat, low-glare, LCD, touchscreen monitor
  Keyboard platform and support arm
  Flexible, customized positioning
  On-board documentation and Help

System Dimensions:
Width: 111.8 cm / 44 inches
Depth: 73.7 cm / 29 inches
Height: 130.2 cm / 51.25 inches
Weight: 366 kg / 807 pounds

POWER
Line Voltage: Dedicated, single phase AC power line
North America: 120 V AC
Continental Europe: 200-240 V AC
Line Frequency:
North America: 50-60 Hz
Continental Europe: 50-60 Hz
 

ENVIRONMENT
Average Heat Output: 4,100 BTUs per hour
Operating Temperature: 15°-30°C / 59°-86° F
Ambient Relative Humidity: 15%-75% RH non-condensing
Altitude: -0.1524/2.439 km / -500/8000 feet
Plumbing: No water or drain required; Self-contained, on-board liquid waste management eliminates special requirements for off-board plumbing
 

COMMUNICATIONS
Bidirectional interface for ASTM and Kermit protocols, including broadcast download 4 RS 232 serial ports
    

e-Connectivity® Interactive System Management 

*Some or all types of specimens or suggested reference interval or cutoff for these analytes are not approved or cleared for market in the United States
**For Red Cell Folate 


VITROS® ECiQ



© Ortho-Clinical Diagnostics N.V, 2003-2013. This site is published by Ortho-Clinical Diagnostics N.V. which is solely responsible for its contents. Product availability is subject to fulfillment of regulatory requirements in each market.  This site was written for healthcare professionals in Belgium only.